Ambient Lighting
Coves, recessed downlights and indirect ceiling washes providing the base layer, dimmable from cleaning mode at full output down to two per cent for late-night trading.
Product Directory
Seven curated categories covering every visible surface, seat and light fitting in a modern gaming venue — specified, manufactured and installed under one programme.

Catalogue · Division 02
Layered lighting schemes engineered for gaming environments, where luminance, glare control, surveillance clarity and atmosphere all have to be satisfied at once.

Overview
Gaming floors operate at low ambient levels, which makes every luminaire decision consequential. Too little contrast and the room feels flat and cheap; too much and guests experience glare, surveillance cameras lose detail and staff report eye fatigue across a shift.
We design in layers — ambient, task, accent, decorative and emergency — and we model each layer before specification. Every scheme is delivered with a luminance study showing lux levels at table felt, aisle floor, cashier counter and circulation, so performance is verifiable rather than assumed.
Lighting scope
We supply the fittings, the drivers, the control platform and the commissioning. A single team is responsible for whether the room looks right on opening night.
Coves, recessed downlights and indirect ceiling washes providing the base layer, dimmable from cleaning mode at full output down to two per cent for late-night trading.
Dedicated luminaires positioned to light the felt and player hands evenly, with tight beam control that avoids reflection on chip stacks and dealer sightlines.
Statement chandeliers, suspended sculptural elements and architectural coves that establish scale at arrival and provide the property's signature night-time image.
Scene-programmed schemes with guest-accessible presets, warm colour temperatures, concealed sources and dimming curves tuned to feel gradual rather than stepped.
Hand-blown glass, machined metal and textile-shaded fittings produced by European and Australian ateliers, configured to the venue's dimensions and palette.
Exterior architectural schemes with IP66-rated fittings, dark-sky compliant aiming, and programmable sequences for events without resorting to garish colour washes.
LED platforms with L90/B10 lifetimes above 60,000 hours, driver efficiency above ninety per cent, and payback modelling against existing installed load.
Occupancy-aware zones in back-of-house and circulation, daylight compensation at glazed frontages, and integration with the building management system.
DALI-2 and proprietary platforms with scene programming for trading, cleaning, event, promotional and emergency modes, delivered with a written scene schedule.
Full documentation set: luminance calculations, luminaire schedules, switching and dimming diagrams, and an aiming and focus programme for site commissioning.

Technical detail
An excellent specification installed without focus and scene work will underperform a modest one that has been properly commissioned. We attend site at night, aim every adjustable fitting by hand, and programme scenes with the operations manager present so the settings reflect how the venue actually trades.
The commissioning record is issued as a document: scene names, channel levels, fade times, transition triggers and the reasoning behind each. If a control panel is later replaced, the venue can restore the design intent exactly rather than guessing.
We return sixty days after opening for a review visit, because most operators discover their real preferences only once the venue is running at full capacity.
Indicative technical specification — gaming floor lighting
| Ambient level | 80–150 lux at floor, zoned by activity and time of day |
|---|---|
| Table felt level | 300–450 lux with ±10% uniformity across the layout |
| Colour temperature | 2700 K VIP and lounge, 3000 K main floor, 3500 K back-of-house |
| Colour rendering | CRI ≥ 90, R9 ≥ 50 on guest-facing luminaires |
| Glare | UGR ≤ 19 at seated player eye height |
| Control protocol | DALI-2 with emergency test reporting and BMS integration |
| Dimming range | 1–100% with logarithmic curve, flicker < 5% at all levels |
| Lifetime | L90/B10 at 60,000 hours minimum, driver serviceable in place |
Advantages
Typical applications
Lux, uniformity and glare targets are modelled, then measured on site and signed off against the model.
Levels and finishes are reviewed with the surveillance manager so camera detail is never compromised for atmosphere.
Installed load, annual consumption and payback are documented against the previous scheme before approval.
Drivers and lamps are accessible without dismantling ceilings, and spares are held in an agreed attic stock.
Start a project